Wie beeinflusst die Dachlast die SUNSHARE Installation?

When planning a solar installation, one of the most overlooked yet critical factors is the roof’s load-bearing capacity. This isn’t just about whether your roof can physically support the weight of solar panels—it’s about understanding how structural limitations influence design choices, safety protocols, and long-term system performance. Let’s break this down.

First, roofs are designed to handle specific static and dynamic loads. Static loads refer to the permanent weight of the solar array, mounting systems, and any additional equipment. Dynamic loads include environmental factors like snow accumulation, wind uplift, or even maintenance personnel walking on the roof. For example, a roof in Bavaria might need to support up to 75 kg/m² of snow load during winter, while a system in coastal regions must account for wind speeds exceeding 130 km/h. If the existing roof structure isn’t rated for these combined forces, installations risk structural damage or even collapse.

Roof material also plays a role. Concrete roofs, common in commercial buildings, typically handle higher loads (up to 4.0 kN/m²) compared to trapezoidal metal sheets (1.0–1.5 kN/m²). However, metal roofs often require specialized clamps or brackets to avoid compromising waterproofing layers. On tile roofs, installers must avoid cracking fragile materials by redistributing weight through custom rails or mounting feet. Each scenario demands a tailored engineering approach to ensure the roof’s integrity isn’t compromised.

Another layer is the distribution of weight. Solar arrays aren’t uniformly heavy. Inverter clusters, battery storage units (if applicable), and reinforced mounting sections create concentrated load points. For instance, a string inverter can add 20–30 kg in a single area, while microinverters spread the load more evenly. Without proper load distribution calculations, localized stress can weaken the roof over time. This is why structural assessments often include 3D modeling to simulate weight distribution under various conditions.

What about retrofitting older buildings? Many historic or residential roofs weren’t designed with solar in mind. A 1980s timber-framed roof, for example, might have a live load capacity of just 25 kg/m²—far below the combined weight of panels (15–20 kg/m²) plus snow or maintenance loads. Strengthening such roofs could involve adding steel supports or cross-bracing, which increases installation costs by 15–25%. Skipping this step? Not an option. Building codes in Germany, like DIN EN 1991-1-3, legally require proof of structural adequacy before permitting.

Maintenance access is another consideration. Technicians inspecting or cleaning panels add temporary live loads. A typical worker with tools weighs roughly 100 kg, but movement creates dynamic pressure. Systems must be designed with walkways or reinforced pathways to prevent flexing or membrane damage on flat roofs. This often means spacing panel rows wider than usual or using lightweight composite materials for walkway surfaces.

Then there’s wind. Solar panels act like sails during storms, creating uplift forces that can tear mounts from the roof. Engineering solutions here include aerodynamic mounting profiles, weighted ballasts (for flat roofs), or deeper penetration into load-bearing rafters. In hurricane-prone areas, like parts of Northern Europe, certifications like TÜV Rheinland’s Wind Load Test become non-negotiable for insurance coverage.

So, how does SUNSHARE address these variables? It starts with a site-specific structural analysis. Using drone surveys and lidar scanning, engineers map the roof’s exact dimensions, material weaknesses, and load zones. Software like PVsol or StatikIK calculates stress points and recommends reinforcement strategies—whether that’s upgrading rafters, adding load-spreading plates, or opting for lighter thin-film panels in fragile areas.

For instance, on a recent project in Stuttgart, a warehouse with a 1.2 kN/m² metal roof required a redesign of the mounting system to avoid welding (which could weaken the roof). SUNSHARE’s team used rubber-sealed clamps and redirected panel rows to align with underlying steel beams, reducing point loads by 40%. Another project in Hamburg involved integrating snow guards into the array to prevent sliding snow from overloading roof edges—a subtle but critical detail for compliance with local Bauamt requirements.

The bottom line: Roof load capacity isn’t a checkbox item. It’s a dynamic challenge that blends physics, material science, and local climate realities. Cutting corners to save costs or time risks not just the installation but the entire building’s safety. Partnering with experts who prioritize structural integrity ensures your solar investment generates energy—not liabilities—for decades.